The Modal Shop offers a variety of transfer standard reference accelerometers certified to ISO 17025. The Modal Shop's A2LA scope of accreditation can be seen here. Single and double ended sensor options are available as verification, transfer, low frequency, and shock calibration standards. All sensors include ICP sensor signal conditioning, cables, and laser primary calibration data.
Transfer standard reference accelerometer, for use as a single-ended verification or transfer standard accelerometer. Includes ICP sensor signal conditioner, sensor cables and laser primary calibration data from 5 Hz to 11 kHz, A2LA certified. | |
Transfer primary reference standard accelerometer, for use as a single-ended transfer calibration accelerometer for working reference standards. Includes ICP sensor signal conditioner, sensor cables and laser primary calibration data from 5 Hz to 20 kHz, A2LA certified. | |
Transfer standard reference accelerometer, for use as a single-ended low frequency calibration verification accelerometer. Includes ICP sensor signal conditioner, sensor cables and laser primary calibration data from 0.1 Hz to 4 kHz, A2LA certified. | |
Transfer standard reference accelerometer, for use as a single-ended shock calibration verification accelerometer. Includes ICP sensor signal conditioner, sensor cables and laser primary calibration at 100 Hz, frequency calibration from 10 Hz to 10 kHz and amplitude linearity from 100 g to 10 kg, A2LA certified. |
Transfer standard reference accelerometer and ICP sensor signal conditioner, calibrated as a system, for field calibration of 9100 series Portable Vibration Calibrators. Includes report generation workbook and cabling. Digital volt meter not included. |
Transfer standard reference accelerometer, for use as a double-ended calibration working standard. Includes ICP sensor signal conditioner, sensor cables and laser primary calibration data from 5 Hz to 14 kHz, A2LA certified. | |
Transfer primary reference standard accelerometer, for use as a double-ended calibration working standard. Includes ICP sensor signal conditioner, sensor cables and laser primary calibration data from 5 Hz to 20 kHz, A2LA certified. | |
Transfer standard reference accelerometer, for use as a double-ended low frequency calibration working standard. Includes ICP sensor signal conditioner, sensor cables and laser primary calibration data from 0.5 Hz to 4 kHz, A2LA certified. | |
Transfer standard reference accelerometer, for use as a double-ended shock calibration working standard. Includes ICP sensor signal conditioner, sensor cables and laser primary calibration at 100 Hz, frequency calibration from 10 Hz to 10 kHz and amplitude linearity from 100 g to 10 kg, A2LA certified. |