Portable Shaker Table Vibration Field Tester

Confirm Vibration Alarms | Model 9100D

The 9100D Portable Shaker Table is the ideal tool to field check accelerometers, velocity transducers and proximity probes over a wide operating frequency and amplitude range. The unit is a small, self-contained vibration reference source, used to validate the entire channel of transducers through measurement, monitoring, or recording systems.

CE | UKCA

Highlights

  • Confirm Critical Vibration Shutdown Alarms & Logic
  • Detect Sensor Drift & Amplified Outputs at Key Frequencies
  • Prevent Early or Late Shutdowns Due to Proximity Probe Errors
  • Compliance to API 670 & ISO 9001
  • Reduce Replacement Instrumentation Costs
  • Protect Against Catastrophic Failures
  • Validate Channel Setup Prior to Critical Tests

Applications

  • 4-20 mA Loop Velocity Vibration Transmitters
  • Proximity Probe Testing and Checks for Mismatched Systems
  • Moving Coil Vibration Sensors
  • Condition Monitoring System, Process Control, DCS, and SCADA
  • Portable Vibration Meters and Analyzers


Specifications

View Datasheet | View Specification Sheet

USMetric
Frequency Range (operating) [1]5 Hz to 10 kHz300 to 600k CPM
Maximum Amplitude (50 Hz, 10-gram payload)20 g pk196 m/s² pk
Accuracy of Displayed Acceleration (10 Hz to 10 kHz)±3 % [2]
Operating Battery Life [3]18 hours
Weight18 lb8.2 kg
Sensor Mounting Platform¼-28 Thread Size

[1] 100-gram payload
[2] Calculated by measuring the % difference between the known sensitivity of a reference accelerometer as calibrated by laser primary system per ISO 16063-11 and the measured sensitivity of same reference accelerometer when tested at the same points
[3] As shipped from factory in new condition

Accessories

For a more comprehensive list of accessories, please see the Product Specification Sheet.

ModelDescription
Included
081B20¼-28 to ¼-28 Adaptor
081A0810-32 to ¼-28 Adaptor
M081A63M8 x 1.25 M to ¼-28 M Mounting Stud
081M165M8 x 1 M to ¼-28 M Mounting Stud
PVC-MNT01M8 x 1.25 F Thru Hole Mounting Pad
PVC-MNT02M8 x 1 F Thru Hole Mounting Pad
PVC-HTMNT01Mounting Plate, 3- & 4-Hole High-Temp Vibration Sensors [1]
PVC-HTMNT02Mounting Plate, 3- & 4-Hole High-Temp Vibration Sensors [1]
Suggested
9100-PPASHProximity probe adaptor kit for testing probes mounted inside a probe holder
9100-PPA01Proximity probe adaptor kit for probes with 5 mm or 8 mm tip diameter [2]
9155-MNT93½-20 F to ¼-28 F Mounting Pad
9155-MNT43¼” NPT F Mounting Adaptor to ¼-28 M
9155-MNT73⅜-24 M to ¼-28 M Mounting Stud

[1] Multi-hole mounting plates are convenient but not optimized for the best calibration results. The Modal Shop offers a full line of customized mounting pads validated in our calibration lab for precise results. Contact us for more information.
[2] For metric unit micrometer, use Model 9100-MPPA01

Support

Product Support Included with Purchase

  • NIST Traceable Certificate of Calibration, Accredited to ISO 17025 by A2LA
  • USB Flash Memory Drive: Loaded with CALROUTE Workbook
  • Quickstart Guide Available in English, Chinese, Japanese, Polish, & Russian
  • 2-Year Warranty, Inclusive of Drift/Accuracy
  • Technical Training Webinars Available Upon Request, 24/7 Video Library

New CALROUTE firmware allows technicians to program repetitive test points such as alert and shutdown thresholds at machine running speed. Once programmed via supplied Microsoft Excel® CALROUTE Generation Workbook, the Instrumentation and Controls personnel can test system linearity, accuracy, and shutdown logic in seconds. No additional software is needed.

The Model 9100D mechanically simulates vibration in acceleration, velocity, and displacement in both English and metric scales, running on battery power for up to 18 hours. Vibration is controlled via the internal reference accelerometer, eliminating the need for technicians to manually enter the payload of the sensor under test.

Benefits of Field Testing

  • Reduced Business Interruption Insurance Risk: Calibration, vibration sensor validation, and confirmation of alarms in the vibration protection system are part of the recommended best practices issued by risk engineers representing the world’s primary insurance underwriters. Checks, certifications and audits of the condition monitoring system – like a well maintained fire protection system - make the plant more desirable in a potentially tough insurance market.
  • Cost Savings: Save the maintenance budget, validate old sensors instead of throwing them away. With no moving parts, piezoelectric instrumentation and proximity probes can generate reliable output for years. Too often these sensors are deemed disposable, tossed away and replaced on an annual basis.
  • Promote Safety: Catastrophic machinery failures have dangerous consequences. The vibration protection system is often the last line of defense. Simulating vibration faults and testing the system ensures your teammates are safe on the job.
  • Reduce Downtime: Machinery failure without warning becomes a thing of the past with a field tested vibration protection system.
  • Peace of Mind: When that $1 million asset begins to fail, will you get a critical text to your cell phone from the monitoring system? The calibrator is a low cost insurance policy against vibration protection system failure. Simulating vibration faults at various running speeds allows reliability managers to ensure they will.
  • Improve Personnel Efficiency: Stop “chasing ghosts.” Checking nuisance vibration trips with a portable shaker table identifies cabling faults, scaling errors, programming errors and sensor sensitivity shift allowing analysts to focus the real goal: uptime.
  • Strengthen departmental relationships and confidence: Often false vibration alarm trips are just as costly as late trips. Operations department scoffs as reliability struggles to explain the shutdown to management. Confidence in the system erodes quickly and costs time and money. Field verification promotes confidence and uncovers system errors.

9100D Features

  • Rugged portability
    • Sturdy internal shaker element design with carbon fiber composite armature flexures
    • Legendary protection and quality of Pelican® Cases
      • Watertight, crushproof
      • Two press and pull latches
  • Simple and elegant usability
    • Adjust frequency ranges and amplitude settings with just two dials
    • English or metric units on LCD screen
    • Lightweight at 18 lb (8.2 kg) allowing for easy mobility
    • Battery life up to 18 hours
  • Precision control and stability
    • Integral ICP® quartz reference accelerometer
    • State of the art digital electronics 
  • Ideal for in-situ validation
    • Ensure end-to-end functionality
    • Confirm alarm trip points are set properly
  • Semi-automated testing capability with 9100-CALROUTE
    • pre-program frequency and amplitude points 
    • easily run the same test on multiple sensors
  • Guarantees accuracy and reliability of test with integrated reference accelerometer traceable to NIST
  • Validate from 5 Hz to 10 kHz (300 to 600 000 CPM)
  • Amplitudes up to 20 g

Whether your goal is vibration monitoring loop checking, proximity probe calibration, accelerometer calibration, 4-20 mA transmitter validation, or other vibration system checks, the Model 9100D Portable Shaker Table, a mobile vibration shaker from The Modal Shop, can help promote safety, improve efficiency, and maintain peace of mind.

With an integral, precision quartz reference accelerometer, the shaker table is built with robust carbon fiber composite armature flexure supports, capable of simulating vibration on payloads up to 800 grams. The unit allows calibrations over a frequency range of 5 Hz to 10 kHz, and closed-loop level control makes the shaker much easier to use than other portable field calibrators. Direct BNC connection to the reference accelerometer allows users to check the integrity of the shaker and reference. The device is supplied with an A2LA accredited calibration certificate.