Sound Level Meter Larson Davis LxT Rental

Measure Noise Levels and Report Noise Data

Notice: The SoundTrack LxT is obsolete and no longer our recommended solution. Please see Spartan Sound Level Meter Model 821IH as a recommended replacement and to learn more about Larson Davis' latest offering for occupational noise assessment.

The Larson Davis SoundTrack LxT® Sound Level Meter was developed to meet the unique needs of those involved in workplace noise exposure assessment, plant noise surveys and noise ordinance enforcement. With a sleek ergonomic design, it is able to be held and operated with just one hand.  The LxT is the perfect tool for gathering, analyzing and presenting detailed noise environment data quickly and easily. Results at a price that won't consume your entire instrumentation budget.

Highlights

  • User programmable run modes
  • On-meter storage for multiple setup configurations
  • Threshold exceedance data
  • Class 1 or Class 2 models available
  • Octave band analysis available

Applications

  • Environmental Noise Assessment
  • Community Noise Surveys
  • Traffic Noise Surveys
  • Workplace Noise Exposure Measurement
  • Product Noise Testing
  • Construction Noise Measurements
  • Firearm Acoustic Testing

Specifications

View  complete specifications from manufacturer

Internal Memory256 MB standard, most rental units have 2 GB
Dynamic Range100 dB (38 – 140 dBA standard range)
Frequency WeightingsRMS and Peak A, C, and Z
Time WeightingsRMS Slow, Fast, and Impulse
Power Supply4 AA batteries provide over 16 hours of operation (30 hours with Lithium batteries, not included)

Featured Option

Firearm Acoustic Analysis

The Sound Level Meter Kit Model KLxT-QPR is an ideal tool for gathering, analyzing, and presenting detailed firearm noise data quickly, easily, and concisely. Ideal for suppressor and silencer product testing.

Learn More

Capabilities

  • Built in digital correction between free-field and random incidence microphones
  • Works with any standard 0V prepolarized condenser microphone – high sensitivity 377B02 included unless another requested
  • USB 2.0 Connections for computer connectivity and USB storage
  • User selectable multi-parameter Data Logging (standard to 1s) (as as 100ms with HSLOG option) (*)
  • Real Time 1/1 & 1/3 Octave Frequency Analysis (*)
  • Measurement History allows longer term parameters to be stored simultaneously with Data Logging (e.g., Ln and histogram tables)
  • Exceedance Event Counters: two RMS event counters and three peak event counters (threshold level, event counter and duration for each exceedance)
  • Multiple setup configurations can be stored on each meter
  • Outdoor kits and options available for unattended monitoring
  • G4 Software allows easy meter setup and data download
  • Blaze Software allows additional analysis and reporting
  • (*) Indicates an available option

Internal Storage Capacity (2 GB model)

  • 100 million point Leq Time History (0.1 dB resolution)
  • 30 million 1/1 octave spectra
  • 12 million 1/3 octave spectra
  • 1.2 million Full LxT Measurement Histories (including 1/1, 1/3 octave Leq, plus Dose)

Standards Met

Organization Standard
ANSI ANSI S1.4-1983 (R 2006) plus Amendment S1.4A-1985 (R 2006), Type 1 (SLM)
ANSI S1,43-1997, Type 1 (SLM)
ANSI S1.11-2004 Class 0 (Octave Filter)
ANSI S1.25-1991 Class 1 (Noise Dosimeter)
IEC IEC61672-1 (2002-05) Class 1, Group X IEC60651 (1979) plus Amendment 1 (SLM)
(1993-02) and Amendment 2 (2000-10) Type 1, Group X (SLM)
IEC60804 (2000-10) Type 1, Group X (SLM)
IEC61260 (1995-07) Ed. 1.0 plus Amendment 1 (2001-09), 1/1 and 1/3- octave Bands, Class 0, Group X, all filters
IEC61252 Ed. 1.1 (2002) Type 1 (Noise Dosimeter)
IEC61010-1 Ed. 2.0 (2001-02)
CE Directive 2004/108/EC, IEC 61326-1:2005